Filling Air In One Air Spring
WARNING: This page is about a different variant/trim than selected.
Information
Preconditions for filling an air spring/the air spring system
- Vehicle raised on a lifting platform, wheels freely suspended.
- All components of the system installed and connected.
- Connect the PIWIS Tester to the vehicle and start it. Switch on ignition.
- Start the diagnostic software.
- Select Level control/PASM control unit.
- Select Maintenance/repairs .
- Press F12 to select Replacement of an air spring .
- Select Filling an air spring from the pressure accumulator function.
- Follow the instructions on the Tester.
- Erase fault memory with F8.