Installing Control Unit For Distance Measuring Sensor
Information
Before and after fitting the trim cover for the distance measuring sensor control unit, check the following points:
- The holder for the distance measuring sensor control unit must not show any signs of deformation, which may have been caused, for example, by removing or installing the trim cover for the distance measuring sensor control unit. If the holde for the distance measuring sensor control unit is deformed, carefully push it back into shape.
- If the trim cover is damaged or cracked, replace the trim cover.
- After fitting the trim cover, check that it is seated correctly and securely.
- Installation is performed in reverse order. Pay particular attention to the following:
Tighten screw at the bottom of the holder for the distance measuring sensor control unit with > Tightening torque 2.5 Nm .
Tighten screw at the top of the holder for the distance measuring sensor control unit with > Tightening torque 8 Nm .