LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2020 >> 718 Spyder >> Repair and Diagnosis >> General Information >> Heating, Ventilation & A/C (HVAC) >> 8X Air Conditioning - General -- 718 SPYDER >> WM, 8X00IN Nominal Values For Pressures And Temperatures >> Tools

WM, 8X00IN Nominal Values For Pressures And Temperatures: Tools

Tool denomination Type Tool number Image
Handheld multimeter General workshop equipment > V.A.G 1526E
G16225511Courtesy of PORSCHE CARS NORTH AMERICA, INC.

Information 

General test prerequisites 

Cayman: Close doors, windows and sliding roof.

Boxster: Close doors, windows and convertible top.

Push temperature sensor of the > V.A.G 1526E - Handheld multimeter  into the Centre air vent.

Measure ambient temperature.

Open all air vents.

Switch on the ignition.

Press recirculated air button.

Press A/C MAX button.

Start the engine.

Set engine speed to 2, 000 rpm (start of time measurement).

If the specified nominal values are not reached, the air conditioning must be checked for leaks and repaired.

G16225512Courtesy of PORSCHE CARS NORTH AMERICA, INC.

Centre vent temperature as a function of outside temperature

x-Axle  Outside temperature in °C
y-Axle  Centre vent temperature in °C
G16225513Courtesy of PORSCHE CARS NORTH AMERICA, INC.

High pressure in refrigerant circuit as a function of outside temperature

x-Axle  Outside temperature in °C
y-Axle  High pressure in refrigerant circuit in bar
G16225514Courtesy of PORSCHE CARS NORTH AMERICA, INC.

Low pressure in refrigerant circuit as a function of outside temperature

x-Axle  Outside temperature in °C
y-Axle  Low pressure in refrigerant circuit in bar