Home >> Porsche >> 2019 >> Cayenne Turbo >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 31 (2X Petrol, Exhaust, Engine-Electric - General E-Hybrid -- 9YA - Cayenne (9YA)) >> WM, 2X00IN Pilot Line Fault Finding >> Performing Measurements >> Measurement 5

Measurement 5

WARNING: This page is about a different variant/trim than selected.
WARNING: Incorrect handling of high-voltage components 
  • Electric shock 
  • Short circuit 
  • Fire 
  • Explosion 

    → Only appropriately trained and authorized persons are permitted to work on high-voltage vehicles and components.

    → Required qualification: High voltage technician or high voltage expert.

    → Observe national requirements and legislation for this work.

    → Always use insulated tools, e.g. > VAS 6883 - Insulated Tool Set  when working on these components.

    → Observe general warning notes for working on the high-voltage system.

    > 2X00IN GENERAL WARNING NOTES FOR WORKING ON THE HIGH-VOLTAGE SYSTEM 

Preliminary work for measurement 5  (V8 engine)

  1. Remove cowl panel cover.

    Refer to the appropriate service information.

  2. Release and disconnect connector on electric passenger compartment heater.
    G15257786Courtesy of PORSCHE CARS NORTH AMERICA, INC.

    Electric passenger compartment heater

  3. Perform measurement 5.
    G15257787Courtesy of PORSCHE CARS NORTH AMERICA, INC.

    Measurement 5 (shown as an example)

  4. Resistance measurement on connector at connection point for electric air conditioning compressor (female), pin 3 and electric passenger compartment heater, pin 7

    Refer to the wiring diagram for the pin assignment of the connectors 

    1. 4.1 Setpoint value < 0.5 Ohm 
  5. Evaluating measurement 5 
    1. 5.1 If the measured value is within  the tolerance range, continue with measurement 7  .
    2. 5.2 If the measured value is outside  the tolerance range, visually inspect connectors (also on electric air-conditioning compressor) and repair if necessary.

      After carrying out repairs, repeat measurement 2.