Checking Fuel System (Leak-Testing)
- Spray all connection points of the high-pressure pump with commercially available leak-locating spray and check for pressure gas leaks (air bubbles).
- If the pressure drops ever, cough the threaded connections are perfect:
Spray all components of the fuel high-pressure system with leak-locating spray and check for pressure gas leaks (air bubbles).
- If the pressure drops even though the fuel high-pressure system is perfect:
Spray all test tools with leak-locating spray and check for pressure gas leaks (air bubbles).
- Fix the leak and repeat the leak test.