Filling Air In One Air Spring
WARNING: This page is about a different variant/trim than selected.
Information
Preconditions for filling an air spring/the air spring system
- Vehicle raised on a lifting platform, wheels freely suspended.
- All components of the system installed and connected.
- > 9900 - PIWIS Tester 3 must be connected to the vehicle. Then, start > 9900 - PIWIS Tester 3 .
- Using > 9900 - PIWIS Tester 3 . select Chassis control > Maintenance/repairs > Replacement work on the air spring system > Replacement of an air spring > Filling an air spring
- Lower the vehicle.
- Using > 9900 - PIWIS Tester 3 , select Chassis control > Maintenance/repairs > Replacement work on the air spring system > Replacement of an air spring > Activation of height control