Performing Automatic Verification Of Absence Of Electric Charge Using The PIWIS Tester
WARNING: This page is about a different variant/trim than selected.
Information
The test log for verifying absence of electric charge is created automatically in the PIWIS Tester. Print the test log, sign it and file it in the order folder.
If absence of electric charge could not be verified automatically or if the function could not be run (see PIWIS Tester display), the voltage must be measured manually.
Use > 9900 - PIWIS Tester 3 with > VAS 6558A - high-voltage testing module and the test adapters > VAS 6558/9-6 - high-voltage test adapter HVA 280 .
| High-voltage battery voltage | __________ | V (setpoint < 20 V) |
| Power electronics voltage | __________ | V (setpoint < 20 V) |
| High-voltage charger voltage | __________ | V (setpoint < 20 V) |
| Voltage of power electronics 2 (if fitted) | __________ | V (setpoint < 20 V) |
| Display in instrument cluster: | □ | □ |
| PIWIS Tester display: | □ | □ |
| Absence of electric charge verified automatically: (Both results must be the same) |
YES □ | NO □ |
| Code displayed in the PIWIS Tester: | _____________________________________________________________ | |