Insulation Test
WARNING: This page is about a different variant/trim than selected.
| Measurement as in 2X00IN | Measuring point | Actual values - Positive to shield | Actual values - Negative to shield | Required |
|---|---|---|---|---|
| Measurement 1 | E-box → high-voltage charger, el. passenger compartment heater, charging socket, high-voltage line | MOhm | MOhm | > 550 MOhm |
| Measurement 2 | High-voltage line E-box → high-voltage charger |
MOhm | MOhm | > 550 MOhm |
| Measurement 3 | High-voltage charger, charging socket | MOhm | MOhm | > 550 MOhm |
| Measurement 3.1 | High-voltage charger | MOhm | MOhm | > 550 MOhm |
| Measurement 4 | High-voltage line el. passenger compartment heater | MOhm | MOhm | > 550 MOhm |
| Measurement 4.1 | El. passenger compartment heater | MOhm | MOhm | > 550 MOhm |
| Measurement 5 | Power electronics, electric motor, E-box, high-voltage line | MOhm | MOhm | > 550 MOhm |
| Measurement 6 | Power electronics, 3-phase line, electric motor, traction line | MOhm | MOhm | > 550 MOhm |
| Measurement 6.1 | E-box | MOhm | MOhm | > 550 MOhm |
| Measurement 6.2 | Power electronics, 3-phase line, electric motor | MOhm | MOhm | > 550 MOhm |
| Measurement 7 | Power electronics | MOhm | MOhm | > 550 MOhm |
| Measurement 8 | Electric motor, 3-phase wiring (U, V, W) | MOhm | MOhm | > 550 MOhm |
| MOhm | MOhm | |||
| MOhm | MOhm | |||
| Measurement 8.1 | Electric motor (U, V, W) | MOhm | MOhm | > 550 MOhm |
| MOhm | MOhm | |||
| MOhm | MOhm | |||
| Measurement 9 | High-voltage line, el. A/C compressor | MOhm | MOhm | > 10 MOhm |
| Measurement 9.1 | High-voltage line | MOhm | MOhm | > 550 MOhm |
Sign the test log and file it in the order folder.
Signature: ___________________________________________