Home >> Porsche >> 2018 >> Panamera Base >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 58 (8X Air Conditioning - General - Wagon -- 971 - PANAMERA (971)) >> WM, 8X00IN Safety Regulations For Extraction And Filling Systems >> Safety Regulations For Extraction And Filling Systems

Safety Regulations For Extraction And Filling Systems

WARNING: This page is about a different variant/trim than selected.
WARNING: Incorrect handling of air conditioning servicing equipment. 
  • Unnecessary damage to the environment due to emerging refrigerant. 

    → Before connecting the filling system to the air-conditioning system, make sure that the manual shut-off valves are closed.

    → Before disconnecting the filling system from the air-conditioning system, make sure that the process is complete so that no refrigerant can escape into the atmosphere.

    → After the purified refrigerant has been filled into an external compressed gas bottle from the filling system, the manual shut-off valves on the bottle and on the filling system should be closed.

    → Do not expose the filling system to moisture or use in a damp environment.

    → Shut off the power supply at the filling system before carrying out maintenance work.

    → An extension cable with cross-sectional area of at least 2.5 mm should be used only when absolutely necessary.

    → In the case of fire, the external bottle should be removed.

    → Fill the oil extracted from the air-conditioning system into a suitable closable container (the refrigerant oil contains small quantities of refrigerant).

    → The filling system must be secured to prevent it from rolling away.

    → Set down and use the air conditioning servicing equipment with refrigerant R1234yf only in cool, well-ventilated places.

    → Protect from heat and direct sunlight and do not set down and use in areas with temperatures above 50°C.

    → Do not set down and use in or near cellars or other lower-lying areas.

    → Only set down and use in areas with adequate air flow (complete air exchange at least once per hour in the workshop area and 3 times per hour in lower-lying areas, e.g. in assembly groups).