Home >> Porsche >> 2017 >> Panamera Turbo >> Repair and Diagnosis >> External Pages >> Different car >> Section 28 (43 Leveling System, Air Suspension, Damper Control 4.0L Turbo Hybrid -- 971 - PANAMERA (971)) >> WM, 430115 Calibrating The Levelling System >> Procedure: Measured Actual Value Is Not Accepted

Procedure: Measured Actual Value Is Not Accepted

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2023 Porsche Panamera, 2022 Porsche Panamera, 2021 Porsche Panamera, 2020 Porsche Panamera, and 2019 Porsche Panamera. However, it is still accessible from the selected car via links, so may be relevant.

Information 

During height sensor calibration, a height value that is entered may not be accepted by the Porsche System Tester.

In this case, at least one value is implausible, i.e. the value is not within the tolerance range for the vehicle height stored in the control unit.

The reason for this may be as follows:

  1. Measure the vehicle body height again.
  2. If the measured values are identical to the values measured previously, check the front level sensor and rear level sensor for damage.

    > WM, 947819 REMOVING AND INSTALLING FRONT ANGLE SENSOR FOR HEADLIGHT BEAM ADJUSTMENT (HBA)

    > WM, 947919 REMOVING AND INSTALLING REAR ANGLE SENSOR FOR HEADLIGHT BEAM ADJUSTMENT (HBA)

  3. If level sensors are intact, the specified vehicle level must be adjusted in steps.

    Information 

    The Porsche System Tester accepts height values with a required value tolerance of +/- 25 mm.

    If the measured value is not within this tolerance range when adjusting the vehicle level step-by-step, the limit value that is closer to tolerance range must be entered as the Actual value in the Porsche System Tester.

    1. 3.1 Enter the mean value determined from the actual/required value at the affected vehicle position instead of the unaccepted actual value.

      Example: 

      Height measurement results in 460 mm (18.0 in.) at the front left.

      Actual value: 460 mm (18.0 in.); setpoint value: 414 mm (16.3 in.).

      (Actual value + setpoint value)/2 = mean value 

      (460 mm + 414 mm)/2 = 437 mm (17.2 in.).

      Enter 437 mm (17.2 in.) into the PIWIS Tester  .