LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2017 >> Macan S >> Repair and Diagnosis >> External Pages >> Different car >> Section 767 (91 - Radio, Stereo, Telephone, On-Board Computer) >> WM 917225 Calibrating Surround View camera >> Preliminary work

Preliminary work

WARNING: This page is about a different car, the 2016 Porsche Macan and 2015 Porsche Macan. However, it is still accessible from the selected car via links, so may be relevant.

Information 

Calibrating the Surround View camera balances the tyres, chassis tolerances and installation tolerances of the camera.

Information 

Calibration must only be performed on level ground.

The required surface area for successful calibration is approx. 9 x 6 m.

On vehicles with air suspension, switch on ignition, close the doors and set the air suspension to Comfort  .

The following basic requirements must be observed:

Information 

When calibrating the vehicle for the first time using the calibration system WE 1793  , the control unit may be flash-programmed automatically to a new software version by PIWIS Tester 3 9900  .

  1. Left calibration mat
  2. Front camera
  3. Right calibration mat
  4. Right camera mirror
  5. Rear camera
  6. Left camera mirror
G12837171Courtesy of PORSCHE CARS NORTH AMERICA, INC.
  1. Park the vehicle on a level, open surface.
  2. Position the charger in such a way that it is not in the direct line of vision of the front camera.
  3. Clean the calibration mats with a cloth or soft brush.
  4. Align calibration mats for the calibration system WE 1793  .

Align star symbols on the calibration mats with the height at the center of the front axle.

The calibration mats must be aligned parallel to the vehicle.

Distance from calibration mats to vehicle: approx. 20 - 50 mm.

The distance between the calibration mat and vehicle must be the same on both sides.

The difference in the distance between the front and rear calibration mats must not be more than 5 mm.