LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2017 >> Macan S >> Repair and Diagnosis >> External Pages >> Different car >> Section 765 (58 - Rear Door, Central Locking) >> WM 587355 Replacing rear door control unit >> Replacing rear door control unit

Replacing rear door control unit

WARNING: This page is about a different car, the 2016 Porsche Macan and 2015 Porsche Macan. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Voltage drop
  • Risk of irreparable damage to control unit
  • Risk of damage to control unit
  • Fault entries in the control unit
  • Coding in the control unit is aborted
  • Malfunctions in control unit, even during programming

→ Prior to disconnecting the control unit, switch off ignition and remove ignition key.

→ Ensure that the power supply is not interrupted during programming.

→ Connect a battery charger with a current rating of at least 90 A to the vehicle battery.

Information 

The PIWIS Tester 3 9900  instructions take precedence since the description may be different with later Tester releases.

The procedure described here has been structured in general terms. Different text or additional information may appear in PIWIS Tester 3 9900  .

  1. Switch off ignition and replace control unit. → 587355 REPLACING REAR DOOR CONTROL UNIT 
  2. Connect the PIWIS Tester to the vehicle and start the Tester. Switch on ignition.
  3. Select the vehicle type and start the diagnostic application.
  4. Select the required control unit, e.g. Rear left door  in the overview  .
  5. Extended identification  must now be selected.
  6. Enter the vehicle identification number  and press Enter.
  7. Maintenance/repairs  must then be selected.
  8. Control unit replacement  must now be selected. Then press [F12].
  9. Select Write data  , press [F12] and then press [F8] to start. The data is now loaded.
  10. The Tester displays the message Data has been written  . Press [F12] to continue.
  11. Codings/adaptations  must now be selected.
  12. Automatic coding  must now be selected. Then press [F12] to continue.
  13. When the message Coding has been completed successfully  appears, press [F12] to continue.
  14. Read out the fault memory and erase it if necessary.
  15. Check the function of the door control unit.