Preliminary Work
WARNING: This page is about a different car, the 2014 Porsche Cayenne, 2013 Porsche Cayenne, 2012 Porsche Cayenne, and 2011 Porsche Cayenne. However, it is still accessible from the selected car via links, so may be relevant.
Information
- Calibration of the fuel level sender is required after replacing the fuel tank, fuel level sender or instrument cluster.
- The fuel level sender does not have to be calibrated if the battery is disconnected or if a plug connection on the instrument cluster or sender is disconnected. The values remain stored on the instrument cluster.
- The fuel tank must be completely empty before starting calibration.
- Empty the fuel tank completely.
- Wait for a short time (approx. 2 minutes) to allow the fuel-level sensor to settle down to the level.