Checking Hydraulic Tappets
Test conditions:
Engine must be at operating temperature.
The valve on the hydraulic tappet you are checking must be closed.
- Use adapter T40058 and an angled ring wrench to turn the crankshaft in direction of rotation of the engine -arrow- until the valve on the hydraulic tappet you are checking is closed.
- Measure the amount of play between the cams and rocker arm.
- 2.1.
- 2.2. Press the rocker arm down -arrow-
.
Information
Defective or worn hydraulic tappets cannot be repaired, but must be replaced.
- 2.3. If you can slide a feeler gauge 0.20 mm between the cams and rocker arm, replace the hydraulic tappet.
- 2.4. Replace hydraulic tappet. → 150520 REMOVING AND INSTALLING CAMSHAFTS