LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2016 >> Panamera Exclusive >> Repair and Diagnosis >> Suspension >> Electronic Suspension >> 43 - Level Control, Air Suspension -- PANAMERA (970) >> WM 430115 Calibrating The Levelling System (Except PANAMERA GTS, PANAMERA Turbo S, PANAMERA 4 Executive, PANAMERA Platinum Ed., PANAMERA 4 Platinum Ed.) >> Checking >> Calibration Procedure

Calibration Procedure

Adhere strictly to the information provided under "Conditions for carrying out calibration"!

Always carry out the "Calibration procedure" step-by-step  until calibration is complete!

  1. Adjust the vehicle to Normal Level.
  2. Apply the electric parking brake.
  3. Close the doors and tailgate.
  4. Erase the fault memory  .

    To do this, connect the Porsche System Tester. Select >>Levelling system/PASM << >>Fault memory <<

    >>Erase fault memory << in the control unit overview.

    Follow the instructions on the Porsche System Tester.

  5. Perform Height sensor system component test  .

    Select >>Maintenance/repairs << >>Height sensor system component test << in the menu.

    Follow the instructions on the Porsche System Tester.

  6. Perform height sensor calibration  .

    Select >>Maintenance/repairs << >>Height sensor calibration << in the menu.

    Follow the instructions on the Porsche System Tester.

    1. 6.1. Determine the actual axle height values  .

      Determine the actual values of the axle heights at the measuring points and enter these values in the Porsche System Tester.

      Press "Enter" to confirm! 

      Save the actual values! Do not go into the fault memory afterwards. 

    2. 6.2. If an implausible value is entered (actual value is not accepted), measure the height again and enter the value.

      Follow the instructions on the Porsche System Tester.

      Do not go into the fault memory - continue with Step 7! 

      Otherwise, calibration will be aborted (see " CONDITIONS FOR CARRYING OUT CALIBRATION  ", last condition!). 

  7. Completion of height sensor calibration  must now be selected.

    Select >>Drive links/Tests << >>Completion of height sensor calibration <<.

    Follow the instructions on the Porsche System Tester.

    When >>Completion of height sensor calibration << is completed successfully, >>Result  << >>Function completed  << is displayed!

  8. Erase the fault memory  .

    Select >>Fault memory << >>Erase fault memory <<.

    Follow the instructions on the Porsche System Tester.

    Levelling system calibration is complete! 

    When calibration is complete, the vehicle does not adjust automatically to Normal Level. The height values can only be checked after test-driving the vehicle.