Home >> Porsche >> 2016 >> Panamera Exclusive >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> General Servicing >> 8X - Air Conditioning - General -- PANAMERA (970) >> WM 8X00IN Nominal Values For Pressures And Temperatures (Except PANAMERA S Executive, PANAMERA Executive, PANAMERA 4 S Executive, PANAMERA Turbo Executive, PANAMERA GTS, PANAMERA 4S Sport Edition, PANAMERA 4 Executive) >> Information >> Procedure And General Test Prerequisites

Procedure And General Test Prerequisites

Information 

Information 

Information 

  1. Connect air conditioning service device. → WM 870317 DRAINING AND FILLING REFRIGERANT .
  2. Measure outside temperature with a thermometer.
  3. Open all air outlet vents on the dashboard, center console and B-pillar (direct the blower near the test person if necessary).
  4. Insert sensor of the temperature measuring device approx. 4 cm into the middle of the left center vent. 
  5. Check stopwatch and keep an eye on the relevant temperature and high pressure on the air conditioning service unit.
  6. Switch on ignition.
  7. Hybrid vehicles: Check battery temperature of HV battery. Temperature must be < 35 °C. 
  8. Open driver's and passenger's side windows and close sliding roof.
  9. Press A/C Max button.
  10. Start the engine and leave it running at idle speed (do not rev engine unnecessarily after starting!).

    Hybrid vehicles:  Establish driving readiness (with or without combustion engine running).

  11. Operate air conditioner for five minutes at idle speed.
  12. Increase engine speed  depending on engine type and maintain a constant engine speed for two minutes  . Start the time measurement immediately.
    1. 12.1. Increase engine speed on V6 petrol vehicles to 2, 000 RPM  .
    2. 12.2. Increase engine speed on V8 petrol vehicles to 1, 900 RPM  .
    3. 12.3. Increase engine speed on diesel vehicles to 1, 500 RPM  .
    4. 12.4. Hybrid vehicles:  Not necessary. Continue with Step 13.
  13. Note center vent temperature and pressure values after two minutes.
  14. Compare values (center vent temperature and pressure values) with the specified tolerances.