Home >> Porsche >> 2016 >> Panamera Edition >> Repair and Diagnosis >> Suspension >> Electronic Suspension >> 43 - Level Control, Air Suspension -- PANAMERA (970) >> WM 431955 Replacing Rear Level Sensor (Except PANAMERA Executive, PANAMERA GTS, PANAMERA Turbo S, PANAMERA 4 Executive, PANAMERA Platinum Ed., PANAMERA 4 Platinum Ed.) >> Replacing Rear Level Sensor >> Calibrating Level Sensor

Calibrating Level Sensor

Information, measuring points, procedure and conditions for calibration: → 430115 CALIBRATING THE LEVELLING SYSTEM .

  1. Connect the Porsche System Tester to the vehicle and start the System Tester. Switch on ignition.
  2. Select the relevant vehicle type using the cursor keys.
  3. Select Level control/PASM using the cursor keys.
  4. Select the Maintenance/repairs menu and run the Calibrate level sensor function.
  5. Read out the fault memory. If the fault is still present, proceed in accordance with Rep. Gr. 4316 Levelling system diagnosis.