Performing Measurement 1.1 And Measurement 2.1
Measurement 1.1
- Open the service flap in the luggage compartment floor.
- Disconnect high-voltage plug connection HVR 40 from the high-voltage battery.
- Connect high-voltage test adapter High-voltage test adapter HVR 40 WE 1586 to the high-voltage battery -1- . Leave the second connection on the test adapter open.
- Perform measurement 1.1.
- 4.1. Nominal value: 2.9 MOhm
Measurement 2.1
- Disconnect high-voltage test adapter High-voltage test adapter HVR 40 WE 1586 from the high-voltage battery.
- Connect high-voltage test adapter High-voltage test adapter HVR 40 WE 1586 to the high-voltage line for the high-voltage charger. Leave the second connection on the test adapter open.
- Perform measurement 2.1.
- 7.1. Nominal value: > 550 MOhm
- Evaluate the test results.
- 8.1. If the specified measured values from measurement 1.1 are not within the tolerance range and the specified measured values from measurement 2.1 are within the tolerance range, continue with measurement 1.2.
- 8.2. If the specified measured values from measurement 2.1 are not within the tolerance range and the specified measured values from measurement 1.1 are within the tolerance range, continue with measurement 2.2.
- 8.3. The measured values from both measurements are not within
the tolerance range.
- 8.3.1. Repeat the measurements.
- 8.3.2. Check measuring equipment and repeat the measurements.
- 8.3.3. Follow both paths for measurement 1.1 and measurement 2.1.
- 8.3.4. Contact Technical Support
- 8.4. The measured values from both measurements are within
the tolerance range.
- 8.4.1. Repeat the measurements.
- 8.4.2. Check measuring equipment and repeat the measurements.
- 8.4.3. Contact Technical Support
Measurement 1.2