LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2016 >> Panamera 4S >> Repair and Diagnosis (Single Page) >> Electrical >> Gauges >> 90 - Instruments -- PANAMERA (970) >> WM 903555 Replacing Gateway Control Unit (Except PANAMERA S Executive, PANAMERA 4 S Executive, PANAMERA Turbo Executive, PANAMERA GTS) >> Reading And Writing Values

Reading And Writing Values

NOTE: Voltage drop
  • Risk of irreparable damage to control unit
  • Risk of damage to control unit
  • Fault entries in the control unit
  • Coding in the control unit is aborted
  • Malfunctions in control unit, even during programming

→ Prior to disconnecting the control unit, switch off ignition and remove ignition key.

→ Ensure that the power supply is not interrupted during programming.

→ Connect a battery charger with a current rating of at least → Nominal value: 40 A  to the vehicle battery.

Information 

The PIWIS Tester II 9818  instructions take precedence since the description may be different with later Tester releases.

The procedure described here has been structured in general terms. Different text or additional information may appear in PIWIS Tester II 9818  .

  1. Connect the PIWIS Tester to the vehicle and start the Tester. Switch on ignition.
  2. Select the vehicle type and start the diagnostic application.
  3. Select the required control unit Gateway  in the overview  and press [F12] to continue.
  4. Select Maintenance/repairs  .
  5. Select Control unit replacement  and press [F12].
  6. Read data  and press [F12].
  7. Press [F8] to start reading out data.
  8. Check the chassis number and press [F12].
  9. Switch off ignition and replace the control unit. → 903519 REMOVING AND INSTALLING GATEWAY CONTROL UNIT .
  10. Switch on ignition. Select the Write data  menu (procedure described above), press [F12] and then press [F8] to start installing the data that was read out.
  11. The Tester displays the message Data has been written  . Press [F12] to continue. Switch ignition off and then on again.
  12. Select Coding  , Automatic coding  to perform coding in accordance with the instructions on the Tester.
  13. Read out the fault memory and erase it if necessary.