Switch short circuit to ground: Diagnosis/troubleshooting
WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2005 Porsche 911, 2004 Porsche 911, 2003 Porsche 911, 2002 Porsche 911, and 2001 Porsche 911. However, it is still accessible from the selected car via links, so may be relevant.
DIAGNOSIS/TROUBLESHOOTING FOR FAULT CODE 2
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Check input signals for convertible top switch |
|
Convertible-top button not actuated is displayed (both input signals indicate open) Step 2 |
Step 4
Step 6 |
| 2 | Check input signal open on convertible top control unit using alarm system control unit |
|
< 0.3V
approx. 9 V to 10 V Step 3 |
Step 9 |
| 3 | Check input signal close on convertible top control unit using alarm system control unit |
|
< 0.3V
>11 V Step 13 |
Step 9 |
| 4 | Check convertible top switch input signal open on convertible top control unit |
|
< 5
Step 13 |
Step 5 |
| 5 | Check wire between convertible top switch open and convertible top control unit for short circuit to ground |
|
< 5 Step 8 |
Repair wiring harness ->End |
| 6 | Check convertible top switch input signal close on convertible top control unit |
|
< 5
Step 13 |
Step 7 |
| 7 | Check wire between convertible top switch close and convertible top control unit for short circuit to ground |
|
< 5 Step 8 |
Repair wiring harness ->End |
| 8 | Check wires between convertible top switch and convertible top control unit for short circuit |
|
Step 11 | Repair wiring harness ->End |
| 9 | Check wires between alarm for motor and convertible top control unit for short circuit to ground |
|
Step 10 | Repair wiring harness ->End |
| 10 | Check wires between alarm system control unit and convertible top control unit for short circuit |
|
Step 12 | Repair wiring harness ->End |
| 11 |
|
->End | ||
| 12 |
|
See alarm system diagnosis | ||
| 13 |
|
->End | ||