Home >> Porsche >> 2016 >> Macan S >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Gauges & Instrument Panels >> 90 - Instruments >> WM 902525 Eliminating symptoms in body interior: Reprogramming instrument cluster (Instrument cluster does not work/selector lever blocked/SY0715) >> Re-programming instrument cluster

Re-programming instrument cluster

Before doing any other work, read out the instrument cluster software version using the PIWIS Tester:

  1. Highlight the instrument cluster in the 'control unit overview  '.
  2. Read off the version shown in the "Software version  " line in the "Extended identifications  " menu:

    If the existing software version is either 0579 or 0585 

    carry out  the remedial action procedure described below, starting from Step 3  (Reprogramming instrument cluster).

  3. Re-program  the instrument cluster  using the PIWIS Tester with test software version 16.000 installed:
    1. 3.1. Carry out general preliminary work for control unit programming as described in → 9X00IN BASIC INSTRUCTIONS AND PROCEDURE FOR CONTROL UNIT PROGRAMMING USING THE PIWIS TESTER - "PRELIMINARY WORK" .
    2. 3.2. The basic procedure for control unit programming is described in: → 9X00IN BASIC INSTRUCTIONS AND PROCEDURE FOR CONTROL UNIT PROGRAMMING USING THE PIWIS TESTER .
      Required PIWIS Tester software version: 16.000  (or higher)
      Type of control unit programming: Carry out control unit programming using the 'Campaign' function in the Additional menu  on the PIWIS Tester by entering a programming code.
      Programming code: E9K7S 
      Programming sequence: Read and follow the information and instructions on the PIWIS Tester  during the guided programming sequence.
      Do not interrupt programming  .
      Software version programmed during this campaign: 1592 
      When programming is complete, the software version can be read out of the instrument cluster in the → 'Extended identifications'  menu using the PIWIS Tester.
      Procedure in the event of error messages appearing during the programming sequence: 9X00IN BASIC INSTRUCTIONS AND PROCEDURE FOR CONTROL UNIT PROGRAMMING USING THE PIWIS TESTER - "FAULT FINDING" .
      Procedure in the event of abnormal termination of control unit programming: Repeat control unit programming by entering the programming code again.
    3. 3.3. Carry out general subsequent work for control unit programming as described in → 9X00IN BASIC INSTRUCTIONS AND PROCEDURE FOR CONTROL UNIT PROGRAMMING USING THE PIWIS TESTER - "SUBSEQUENT WORK"