Safety Regulations For Extraction And Filling Systems
- Unnecessary damage to the environment due to emerging refrigerant.
→ Before connecting the filling system to the air-conditioning, make sure that the manual shut-off valves are closed.
→ Before disconnecting the filling system from the air-conditioning, make sure that the process is complete so that no refrigerant can escape into the atmosphere.
→ After the purified refrigerant has been filled into an external compressed gas bottle from the filling system, the manual shut-off valves on the bottle and on the filling system should be closed.
→ Do not expose the filling system to moisture or use in a damp environment.
→ Shut off the power supply at the filling system before carrying out maintenance work.
→ An extension cable with cross-sectional area of at least 2.5 mm 2 should be used only when absolutely necessary.
→ In the case of fire, the external bottle should be removed.
→ Fill the oil extracted from the air-conditioning system into a suitable closable container (the refrigerant oil contains small quantities of refrigerant).
→ The filling system must be secured to prevent rolling.