Conditions For Carrying Out Calibration
WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2018 Porsche Cayenne, 2017 Porsche Cayenne, 2016 Porsche Cayenne, 2015 Porsche Cayenne, and 2014 Porsche Cayenne. However, it is still accessible from the selected car via links, so may be relevant.
Information
- Calibration can only be carried out while the vehicle is stationary .
- The vehicle must stand "floating" on the measuring platform to avoid straining the axles .
- Calibration is also required for the variants with "steel springs - PASM". The headlight beam adjustment (HBA) sensors are also calibrated .
- Before calibration is performed, the vehicle must be adjusted to Normal level and the Height sensor system component test must be carried out!
- Ensure that tyre pressures have been adjusted to the respective tyre specifications. (>>4405IN Wheels and tires)
- The vehicle is raised and lowered during the height sensor system component test and then adjusts to the correct level!
- The measured values for the vehicle height must correspond approximately to the values specified under Adjustment values for suspension alignment . An implausible value will not be accepted. For the current comparative values for the vehicle height, please refer to the adjustment values for suspension alignment → 4495TW ADJUSTMENT VALUES FOR SUSPENSION ALIGNMENT
- Do not cancel calibration! If calibration is interrupted, the fault code 000286 "Customer service mode not complete" remains stored and is active! A warning appears in the instrument cluster. Select >>Drive links/checks<< in the menu. Delete the fault memory and perform calibration again!