Throttle Valve
Necessary after:
- Re-programming DME control unit
- Replacing DME control unit
- Replacing throttle valve
Information
Consequences of Tester adaptation if conditions for automatic adaptation are not met (violated boundary condition):
- For a fault entry in the load detection range (P0068 + P1069... P1077), the limits are extended in order to prevent incorrect detections .
- This extension is cancelled if an adaptation is performed when the conditions for automatic adaptation are met, or after 15 warm-up cycles at the latest .
- (Warm-up cycle = coolant temperature increases by more than 23 °C after start-up and reaches at least 73 ° C)
- Following manual throttle valve adaptation when ambient conditions are not met, throttle valve adaptation is carried out again automatically as soon as the ambient conditions are met .
- There is NO 30-second waiting time here, but a slightly delayed engine start is possible once
.
The ambient conditions for automatic adaptation are as follows:
- Engine off and ignition on for > 30 seconds
- Accelerator pedal not pressed
- Vehicle is stationary
- Power supply for throttle valve adjusting unit is OK
- Coolant temperature 5 °C... 100 °C
- Intake air temperature 5 °C... 30 °C
How?
- Ignition on > 30 seconds if preconditions are met.
or
PIWIS Tester:
- 1.1. Meet preconditions:
- 1.1.1. Engine off.
- 1.1.2. Ignition on.
- 1.2. Select menu:
- 1.2.1. DME
- 1.2.2. Maintenance/repairs
- 1.2.3. Adaptations
- 1.2.4. Throttle valve adaptation
- 1.3. Start function by pressing [F12].
- 1.3.1. Information
- 1.4. Press [F12] for detail view.
Information
- Adaptation values are deleted or stored in EEPROM when ignition is switched off after control unit run-on has ended.
This depends on the run-on period of the engine compartment purge fan.
The run-on period of the engine compartment purge fan AFTER ignition is switched off depends on the engine compartment temperature.
The run-on period is as follows at the following engine compartment temperatures:
- < 45 °C: approx. 50 seconds
- 45... 70 °C: approx. 200 seconds
- > 70 °C: up to 20 minutes
- 1.5. Switch off ignition.
- 1.1. Meet preconditions: