WM 9X00IN Measurement Of Closed-Circuit Current (All Models): Measurement
Read off the measured values after the waiting period specified in the table.
- Switch on ignition for 10 seconds.
- Switch off ignition.
- Open the driver's door and close the rotary latch with a screwdriver while the door is open.
- Lock the vehicle using the central-locking remote control and switch off interior surveillance (press the button on the remote control twice in one second).
- Remove short circuit bridge.
- Read off the closed-circuit current.
Information
- If the value of the closed-circuit current is higher than the value determined in the table, the cause must be established systematically.
- Recommended troubleshooting procedure: With the measuring device connected, remove the fuses of terminal 30 and the relays successively. Observe the values displayed on the measuring device when removing the fuses and relays in order to detect a reduction in current.
- The measured values can vary by approx. 20%.
- The values listed in the table depend on the condition of the battery, the room temperature, the engine temperature and therefore should only be regarded as guidelines.
Reading off the measuring range:
Read off the measuring range only after at least 35 minutes have passed since locking the vehicle.
From to mA 35 min. Until battery is empty max. 30 Control unit Equipment Closed-circuit current in mA Alarm siren Standard 0.89 Battery sensor Standard 0.23 Front BCM, front-end electronics Standard 2.3 Rear BCM, rear-end electronics Standard 4.72 Roof console Standard 0.11 DME Standard 0.05 Steering column adjustment 0.06 Electric steering 0.07 ELV, electronic steering column lock Standard 0 Gateway Standard 0.2 Generator Standard 0.13 Main fuse box Standard 0 Interior surveillance 1.7 Front climate control panel Standard 0.05 Instrument cluster Standard 0.16 Fuel pump control unit Standard 0 Steering column module Standard 0.22 Light switch Standard 0 Engine fan Standard 0 PASM 0.05 Parking brake Standard 0.22 PCM 0.32 PDCC 0 PDK 0.05 PSM Standard 0.11 TPM (Tyre Pressure Monitoring) 0.05 Rain sensor 0.05 Sliding roof 0.05 Seat, FL 0.13 Seat, FR 0.19 Heated seats 0 Stopwatch 0.05 Tank leakage diagnosis Standard 0.05 Door, FL 0.2 Door, FR 0.15 TV tuner 0.15 Convertible top 0 Amplifier 0.08 Wiper Standard 0.08 Ignition lock Standard 0.06 Maximum closed-circuit current 30 mA Calculated closed-circuit current 12.93 mA - Connect battery and read out fault memory. Delete any faults if necessary. → 2X00IN WORK INSTRUCTIONS AFTER DISCONNECTING THE BATTERY