Home >> Porsche >> 2016 >> Cayman Base, Automatic DCT Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 281 (24 - Fuel System - Electronic Ignition -- 911 CARRERA (991)) >> WM 246919 Removing And Installing Oxygen Sensor Upstream Of Catalytic Converter (Except CARRERA "Edition", CARRERA Cabriolet "Edition", Turbo S, CARRERA 4 "Edition", Turbo CABRIO, Turbo S CABRIO, CARRERA 4 Cabriolet "Edition", Gt3, Gt3 RS) >> Installing Oxygen Sensor Upstream Of Catalytic Converter

Installing Oxygen Sensor Upstream Of Catalytic Converter

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2019 Porsche 911, 2018 Porsche 911, 2017 Porsche 911, 2016 Porsche 911, and 2015 Porsche 911. However, it is still accessible from the selected car via links, so may be relevant.

Information 

  1. During re-installation of the oxygen sensor, the thread must be coated with the prescribed lubricant.
    1. 1.1. New oxygen sensors are pre-greased for installation. 
      NOTE: Incorrect handling of oxygen sensors
      • Damage to oxygen sensors
      • Different exhaust emission behavior

      → Do not remove the plastic cap on the thread until just prior to fitting.

      → Protect oxygen sensors from impact of any kind.

      → Do not kink or twist the cables when screwing in the sensors.

      → Do not re-use dirty or damaged components.

  2. Screw in oxygen sensor by hand.
    1. 2.1. Use the same tools as prescribed for removal. 
    2. 2.2. Tighten oxygen sensor according to tightening specifications.

      Tightening torque using prescribed tool 39 Nm (29 ftlb.) 

  3. Route oxygen sensor cable and clip it in at the defined mounting points.
  4. Route oxygen sensor cable in engine compartment and clip into the holder.
    1. 4.1. Close plug connection and insert into the holder.