DIAGNOSTIC TROUBLE CODE (FAULT) OVERVIEW

Fault code Fault text Fault effect
1  Targa roof button, Signal implausible Fault memory, Targa sliding roof can only be closed
2  Targa flap button, Signal implausible Fault memory, the rear flap can only be closed
3  Hall signal, Open circuit Fault memory, Targa sliding roof can only be activated briefly in the direction open/closed until the micro switch
Roof closed  is actuated.
4  Hall supply voltage, Short to ground Fault memory, Targa sliding roof can only be activated briefly in the direction open/closed until the micro switch
Roof closed  is actuated.
6  Targa roof micro switch, Signal implausible Fault memory, Targa sliding roof can only be activated briefly in the direction open/closed (mechanical block is eventually reached).
8  Closing aid micro switch unlocked, Signal implausible Fault memory, closing aid unlocks normally and can be locked normally. Then unlocking is only possible after deactivating the fault status.
9  Closing aid micro switch pre-notch, Signal implausible Fault memory only after the 3rd unsuccessful attempt to lock (with open circuit). The closing aid remains in the pre-notch/locked. Unlocking is only possible through emergency locking.
10  Closing aid micro switch locked, Signal implausible Fault memory, closing aid locks normally. Closing aid continues to be activated until the micro switch
unlocked  is actuated.
12  Closing aid motor blocked Fault memory, closing aid motor is stopped. Closing aid can be activated by the switch for the rear lid in the direction locking.
14  Supply voltage > 15 V or < 9 V Fault memory, it is not possible to activate outside the supply range.
16  Sun blind button, Signal implausible Fault memory, sun blind can only be actuated in the opposite direction.
17  Fault at the sun blind motor output Fault memory, in the case of an open circuit, the sun blind is not operational. In the case of a short to ground in a lead, the sun blind is only operational in one direction.