LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2016 >> 911 Turbo, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 138 (66 - Exterior Equipment -- CARRERA (997)) >> WM 667237 Disassembling And Assembling Spoiler Drive (Pump Unit) (911 Turbo Coupe, 911 Turbo S Coupe, 911 Turbo CABRIO, 911 Turbo S CABRIO) >> Assembling Spoiler Drive (Pump Unit) >> Installing Pump Unit

Installing Pump Unit

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2013 Porsche 911, 2012 Porsche 911, 2011 Porsche 911, 2010 Porsche 911, and 2009 Porsche 911. However, it is still accessible from the selected car via links, so may be relevant.
  1. Pump unit
  2. Wire harness
  3. Hydraulic cylinder, left
  4. Hydraulic line, short
  5. Hydraulic cylinder, right
  6. Hydraulic line, long
  7. Fig 1: Overview Of Spoiler Drive (Pump Unit)
    G09827012Courtesy of PORSCHE CARS NORTH AMERICA, INC.

Information 

Observe allocation of hydraulic lines to pump chambers and their installation position.

The short hydraulic line -2-  goes to the upper pump chamber in the pump unit -1-  . The hydraulic line -2-  points to the center - in direction of bracket -6-  - and upwards -Arrow A-  .

The long hydraulic line -3-  goes to the lower pump chamber in the pump unit -1-  . The hydraulic line -3-  is routed along the pump unit -1-  towards the bottom left -Arrow B-  .

Fig 2: Locating Hydraulic Lines Of Pump Unit
G09827013Courtesy of PORSCHE CARS NORTH AMERICA, INC.

Information 

Counter at the hydraulic line with an open-ended wrench when tightening the banjo bolt.

  1. Screw hydraulic lines onto the pump unit.
    1. 1.1. Fit short hydraulic line -2-  and long hydraulic line -3-  using the long banjo bolts -4-  and new sealing rings -5-  on the pump unit -1-  (-Arrow A-  ) and screw on securely -Arrow B-  . → Tightening torque: 15 Nm (11 ftlb.) 
    Fig 3: Installing Screw Of Hydraulic Lines On Pump Unit
    G09827014Courtesy of PORSCHE CARS NORTH AMERICA, INC.
  2. Move pump motor out.
    1. 2.1. Move pump motor out until Pentosin emerges from the two hydraulic lines -2 and 3-  .

      To do this, connect the -wide contact-  to 8V (+) and the -narrow contact-  to ground (--).

    2. Fig 4: Moving Pump Motor
      G09827015Courtesy of PORSCHE CARS NORTH AMERICA, INC.
  3. Fill hydraulic lines at the pump unit.
    1. 3.1. Dip the ends of the hydraulic lines -2 and 3-  fully into a container filled with Pentosin.
    2. 3.2. Move pump motor to its lower initial position.

      To do this, connect the -narrow contact-  to 12V (+) and the -wide contact-  to ground (--). The lower initial position is reached when the piston in the pump unit moves to the mechanical stop and the amperage rating exceeds 10A. The amperage is measured using the → digital multimeter Bosch MMD 302  .

    3. 3.3. To prevent Pentosin from running out of the hydraulic lines, -2 and 3-  , hold the hydraulic lines up straight after removing them from the container.
    Fig 5: Installing Hydraulic Lines At Pump Unit
    G09827016Courtesy of PORSCHE CARS NORTH AMERICA, INC.