LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2016 >> 911 Turbo, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 134 (20 - Fuel Supply, Control -- CARRERA (997)) >> WM 2001IN Bleeding Fuel System On High-Pressure Side (First Start Function) (All Models) >> Bleeding High-Pressure System >> Performing First Start Routine

Performing First Start Routine

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2013 Porsche 911, 2012 Porsche 911, 2011 Porsche 911, 2010 Porsche 911, and 2009 Porsche 911. However, it is still accessible from the selected car via links, so may be relevant.

Information 

The bleeding process is performed via the First start function using the PIWIS Tester 9718. 

  1. PIWIS Tester 9718  must be connected to the vehicle. Switch on ignition and Tester.
  2. Start the diagnostic program, select the vehicle and highlight the DME  option during control unit selection. Press [F12>>] to start the control unit search.
    Fig 1: Control Unit Search Screen Display
    G09827921Courtesy of PORSCHE CARS NORTH AMERICA, INC.
  3. Find and select the Special functions  menu item. Press [F12>>] to continue.
    Fig 2: Special Functions Menu Item Screen Display
    G09827922Courtesy of PORSCHE CARS NORTH AMERICA, INC.
  4. Select First start  in the menu and press [F12>>] to continue.
    Fig 3: First Start Menu Item Screen Display
    G09827923Courtesy of PORSCHE CARS NORTH AMERICA, INC.
    1. 4.1. The following message is displayed. Press [F12>>] to continue.
      Fig 4: Display - Message Screen
      G09827924Courtesy of PORSCHE CARS NORTH AMERICA, INC.
  5. The next menu item shows what to do next. The sequence must be adhered to because otherwise, the function cannot be guaranteed.
    1. 5.1. Activate the function routine by pressing [F8=Start]. Check how long it takes to run the function.
      Fig 5: Starting Routine Screen Display
      G09827925Courtesy of PORSCHE CARS NORTH AMERICA, INC.
    2. 5.2. Then start the engine.
    3. 5.3. The function ends automatically after one minute.
      Fig 6: Routine Running Screen Display
      G09827926Courtesy of PORSCHE CARS NORTH AMERICA, INC.
  6. Switch off the engine and the Tester.
  7. Pull off the Tester cable at the connection point.