Safety Regulations For Extraction And Filling Systems

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2013 Porsche 911, 2012 Porsche 911, 2011 Porsche 911, 2010 Porsche 911, and 2009 Porsche 911. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: Improper handling of the filling system for the air conditioning.
  • Unnecessary damage to the environment due to emerging refrigerant.

→ Before connecting the filling system to the air-conditioning, make sure that the manual shut-off valves are closed.

→ Before disconnecting the filling system from the air-conditioning, make sure that the process is complete so that no refrigerant can escape into the atmosphere.

→ After the purified refrigerant has been filled into an external compressed gas bottle from the filling system, the manual shut-off valves on the bottle and on the filling system should be closed.

→ Do not expose the filling system to moisture or use in a damp environment.

→ Shut off the power supply at the filling system before carrying out maintenance work.

→ An extension cable with cross-sectional area of at least 2.5 mm 2 should be used only when absolutely necessary.

→ In the case of fire, the external bottle should be removed.

→ Fill the oil extracted from the air-conditioning system into a suitable closable container (the refrigerant oil contains small quantities of refrigerant).

→ The filling system must be secured to prevent rolling.