Installing Turbocharger
- Installation is performed in reverse order. Pay particular attention to the following:
- 1.1. Replace exhaust manifold seal.
- 1.2. Replace fastening nuts.
Grease studs with MicroGLEIT LP 475 .
Tightening torque for securing turbocharger to exhaust manifold:
Tightening torque for securing turbocharger to top bracket:
Information
- Check O-rings on the plug-in couplings and replace them if necessary.
- Clean plug connection and coolant hoses before assembly.
- Coat O-rings and coolant hoses with Kluber Plus Gel (Part No. 000.043.205.93).
- Remove stoppers before fitting the coolant lines and hoses.
- 1.3. Replace O-rings on the coolant lines.
Information
- Replace O-rings.
- Grease O-rings with a light coating of Kluber Syntheso Glep (Part No.: 000.043.204.68).
Replace O-rings on the oil lines.
- 1.4. Coolant lines to turbocharger:
- 1.5. Oil lines to turbocharger:
- 1.6. Tightening torque for exhaust temperature sensor:NOTE: Exhaust emissions temperature sensor fitted incorrectly
- Risk of damage to components
→ Only use prescribed lubricant when installing the sensor.
→ Carefully check the thread for damage and smear the surface with Optimal MF Paste (Part No. 000.043.207.07).
Grease thread with the prescribed lubricant.