Removing Additional Flap (Module)
- Perform emergency operation of additional flaps as described in the Driver's Manual.
- 1.1. Loosen motor.
- 1.2. Move additional flaps to the open position.
- Disconnect plug connection for motor.
- Unclip connector housing.
Information
Screw is accessible through the cut-out in the additional flap.
- Unscrew and remove fastening screws at the sides.
- Unscrew fastening screws at the top.
- Unscrew rear fastening screws.
- Pull additional flaps with drive mechanism up and off.
- Feed out belt strap.