Home >> Porsche >> 2016 >> 911 Turbo, 2D Convertible >> Repair and Diagnosis >> Body & Frame >> Sun Roof/T-Top/Convertible Top >> 61 - Convertible Top, Hardtop -- 911 CARRERA (991) >> WM 610125 Calibrating Convertible Top (CARR. CABRIO, CARR. S CABRIO, CARRERA GTS CABRIO, CARR. 4 CABRIO, CARR. 4S CABRIO, Turbo CABRIO, CARR. 4 GTS CABRIO, Turbo S CABRIO) >> Calibrating Convertible Top

Calibrating Convertible Top

NOTE: Voltage drop
  • Risk of irreparable damage to control unit
  • Risk of damage to control unit
  • Fault entries in the control unit
  • Coding in the control unit is aborted
  • Malfunctions in control unit, even during programming

→ Prior to disconnecting the control unit, switch off ignition and remove ignition key.

→ Ensure that the power supply is not interrupted during programming.

→ Connect a battery charger with a current rating of at least → Nominal value: 40 A  to the vehicle battery.

Information 

The convertible top and convertible-top compartment lid are calibrated using the diagnostic interface in the vehicle and PIWIS Tester II 9818  . The various sensor values (for the convertible top and convertible-top compartment lid) are determined during calibration. For this purpose, the convertible top moves to the end positions "open" and "closed" one after the other. If the sensor values are plausible, these values are stored in the convertible top control unit.

The original calibration values must be deleted from the convertible top control unit before starting calibration.

Information 

The PIWIS Tester II 9818  instructions take precedence since the description may be different with later Tester releases.

The procedure described here has been structured in general terms; different text or additions may appear in PIWIS Tester II 9818  .

  1. PIWIS Tester II 9818  must be connected to the vehicle before starting the System Tester. Switch on ignition.
  2. Select vehicle type.
  3. Select Convertible top  using the cursor keys and press [F12].
  4. Switch to the Maintenance/repairs  menu.
  5. Select Delete calibration  with the cursor keys and press [F12].
  6. Press [F8] to start deleting the calibration values.
  7. The message Calibration deleted  appears on the screen.
  8. Select Start calibration  with the cursor keys and press [F12].
    WARNING: Danger of injury and damage to property!
    • Danger of injury when working on the convertible top

    → No tools or other items should be stored within the movement range of the convertible top.

    → The movement range of the convertible top and side window must be kept clear.

  9. Start convertible top calibration by pressing [F8].
  10. The convertible top moves to the end positions "open" and "closed" one after the other.
  11. The message Calibration successful  appears on the screen.
  12. Press [F12] to exit.
  13. Read out the fault memory  and erase it if necessary.
  14. Perform function test on the convertible top.