WM 9X00IN Measurement Of Closed-Circuit Current (Except PANAMERA S Executive, PANAMERA 4 S Executive, PANAMERA Turbo Executive, PANAMERA GTS): Measurement
Read off the measured values after the waiting period specified in the table.
- Switch on ignition for 10 seconds.
- Switch off ignition.
- Open the driver's door and close the rotary latch with a screwdriver while the door is open.
- Lock the vehicle using the central-locking remote control and switch off passenger compartment monitoring (press the button on the remote control twice in one second).
- Remove short circuit bridge.
- Read off the closed-circuit current.
Information
- If the value of the closed-circuit current is higher than the value determined in the table, the cause must be established systematically.
- Recommended troubleshooting procedure: With the measuring device connected, remove the fuses of terminal 30 and the relays successively. Observe the values displayed on the measuring device when removing the fuses and relays in order to detect a reduction in current.
- The measured values can vary by approx. 20%.
- The values listed in the table depend on the condition of the battery, the room temperature, the engine temperature and therefore should only be regarded as guidelines.
Reading off the measuring range:
Read off the measuring range only after at least 35 minutes have passed since locking the vehicle.
From to mA 35 min. Until battery is empty max. 30 Control unit Equipment Closed-circuit current in mA Display domain calculator ADR Standard 0.06 Alarm siren Standard 1.265 BCM_rear_D1 Standard 2.330 BCM_rear_D2 Standard 2.225 BCM_rear_D3 Standard 0.25 BCM_front_A1 Standard 0.855 BCM_front_A2 Standard 0.88 BCM_front_A3 Standard 0.635 Brake booster Standard 0.035 Roof console Standard 0.205 E_steering Standard 0.135 Rear axle steering Standard 0.075 Gateway_Int. surv. Standard 1.995 Fan control Standard 0.015 Main fuse box HSB Standard 0.02 HV_battery Standard 0.2 HV_charger Standard 0.7 Navigation Standard 0.01 KLSM_combi_switch module Standard 0.335 LDS_EL. IGN. SW._ELV Standard 0.1 Rear power electronics Standard 0.105 Front power electronics Standard 0.13 Rain sensor Standard 0.025 Service_Disconnect Standard 0.05 Aero_CU Standard 0.025 Passenger's door_CU Standard 0.145 Op. + A/C unit_CU Standard 0.035 DME_CU Standard 0.13 EPB_CU Standard 0.025 Driver's door_CU Standard 0.135 Lift_Load_CU 0.015 Lift function_CU 0.165 PASM_CU Standard 0.06 PDK_CU Standard 0.035 PSM_CU Standard 0.055 TPM_CU Standard 0.015 VTS_CU Standard 5 Smart_actuator Standard 0.04 Spindle actuator Standard 0.005 Touch_control panel_CD Standard 0.095 Burmester amplifier Standard 0.11 Selector lever Standard 0.21 Wiper Standard 0.075 Maximum closed-circuit current 30 mA Calculated closed-circuit current 19.01 mA - Connect battery and read out fault memory. Erase any faults if necessary. → 2X00IN WORK INSTRUCTIONS AFTER DISCONNECTING THE BATTERY