Installing Carbon Canister - Usa
WARNING: This page is about a different variant/trim than selected.
Component overview of carbon canister with leakage diagnosis pump
| 1 | Carbon canister |
| 2 | Fastening screws |
| 3 | Thick blue hose |
| 4 | Thin black hose |
| 5 | Electric line |
| 6 | Leakage diagnosis pump |
| 7 | Vacuum line for leakage diagnosis pump |
- Clip electric line -5- at the back of the carbon canister into the brackets.
- Connect vacuum line -7- for the leakage diagnosis pump -6- .
- Plug in electric plug connection on leakage diagnosis pump -6- until the connector engages securely.
- Attach hose connections -3 and 4- to the carbon canister -1- .
- Tighten three fastening screws -2-
on the carbon canister -1-
.
> Tightening torque 9 (6.5 ftlb.) Nm