LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2014 >> Boxster Base, Automatic DCT Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 269 (94 - Lights, Lamps, Switches, Exterior -- 911 CARRERA (991)) >> WM 941625 Programming Headlight Control Unit (Centrally) (Except CARRERA "Edition", CARRERA Cabriolet "Edition", CARRERA 4 "Edition", CARRERA 4 Cabriolet "Edition") >> Programming Headlight Control Unit (Centrally)

Programming Headlight Control Unit (Centrally)

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2019 Porsche 911, 2018 Porsche 911, 2017 Porsche 911, 2016 Porsche 911, and 2015 Porsche 911. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Voltage drop
  • Risk of irreparable damage to control unit
  • Risk of damage to control unit
  • Fault entries in the control unit
  • Coding in the control unit is aborted
  • Malfunctions in control unit, even during programming

→ Prior to disconnecting the control unit, switch off ignition and remove ignition key.

→ Ensure that the power supply is not interrupted during programming.

→ Connect a battery charger with a current rating of at least → Nominal value: 40 A  to the vehicle battery.

Information 

The PIWIS Tester II 9818  instructions take precedence since the description may be different with later Tester releases.

The procedure described here has been structured in general terms. Different text or additional information may appear in PIWIS Tester II 9818  .

  1. PIWIS Tester II 9818  must be connected to the vehicle and ignition switched on.
  2. Start the diagnostic application and select the required vehicle type.
  3. Select Maintenance/repairs  using the cursor keys.
  4. Select Headlight control unit (centrally), Headlight start-up  using the cursor keys and press [F8] to confirm your selection.
  5. As soon as Headlight start-up  , Write chassis number  and Automatic coding  is complete, press [F12] to end the process.
  6. PIWIS Tester II 9818  must be disconnected from the vehicle and ignition switched off.