WM 962755 Replacing Switch Console (All Models): Information
NOTE:
Voltage drop
- Risk of irreparable damage to control unit
- Risk of damage to control unit
- Fault entries in the control unit
- Coding in the control unit is aborted
- Malfunctions in control unit, even during programming
→ Prior to disconnecting the control unit, switch off ignition and remove ignition key.
→ Ensure that the power supply is not interrupted during programming.
→ Connect a battery charger with a current rating of at least → Nominal value: 40 A to the vehicle battery.
Information
The PIWIS Tester II 9818 instructions take precedence since the description may be different with later Tester releases.
The procedure described here has been structured in general terms. Different text or additional information may appear in PIWIS Tester II 9818 .