Home >> Porsche >> 2012 >> Panamera Turbo >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> General Servicing >> 8X - Air Conditioning - General -- PANAMERA (970) >> WM 8X00IN Safety Regulations For Extraction And Filling Systems (Except PANAMERA S Executive, PANAMERA Executive, PANAMERA 4 S Executive, PANAMERA Turbo Executive, PANAMERA GTS, PANAMERA 4S Sport Edition, PANAMERA 4 Executive) >> Safety Regulations For Extraction And Filling Systems

Safety Regulations For Extraction And Filling Systems

WARNING: Improper handling of the filling system for the air conditioning.
  • Unnecessary damage to the environment due to emerging refrigerant.

→ Before connecting the filling system to the air-conditioning, make sure that the manual shut-off valves are closed.

→ Before disconnecting the filling system from the air-conditioning, make sure that the process is complete so that no refrigerant can escape into the atmosphere.

→ After the purified refrigerant has been filled into an external compressed gas bottle from the filling system, the manual shut-off valves on the bottle and on the filling system should be closed.

→ Do not expose the filling system to moisture or use in a damp environment.

→ Shut off the power supply at the filling system before carrying out maintenance work.

→ An extension cable with cross-sectional area of at least 2.5 mm 2 should be used only when absolutely necessary.

→ In the case of fire, the external bottle should be removed.

→ Fill the oil extracted from the air-conditioning system into a suitable closable container (the refrigerant oil contains small quantities of refrigerant).

→ The filling system must be secured to prevent rolling.