| Refrigerant quantity in system (not e-Hybrid) |
Includes Executive |
134a |
580 g |
|
|
| Refrigerant quantity in system |
e-Hybrid |
134a |
580 g |
|
|
| Refrigerant oil in compressor |
not e-Hybrid and Executive |
|
140 cm3 |
|
|
| Refrigerant oil in compressor |
e-Hybrid |
100 cm3 |
|
|
| Refrigerant oil in compressor |
Executive |
110 cm3 |
|
|
| High-pressure cut-off |
All |
32 bar |
|
|
| Low-pressure cut-off |
All |
1.4 bar |
|
|
| Pressure relief valve for purge pressure |
All |
44±4 bar |
|
|
| Fastening screw for pressure and intake pipe on expansion valve, M8 |
-A- |
Tightening torque |
14 Nm (10.5 ftlb.) |
|
|
| Fastening screw for refrigerant line, M8 |
-B- |
Tightening torque |
14 Nm (10.5 ftlb.) |
|
|
| Fastening screw securing intake pipe to compressor, M8 |
-C- |
Tightening torque |
20 Nm (15 ftlb.) |
|
|
| Fastening screw securing pressure line to compressor, M8 |
-D- |
Tightening torque |
20 Nm (15 ftlb.) |
|
|
| Fastening screw securing refrigerant lines to condenser, M8 |
-E- |
Tightening torque |
14 Nm (10.5 ftlb.) |
|
|