Installing Power Distributor (HSB)
WARNING:
Incorrect handling of safety bolts
- Danger of injury
- Loss of torque
→ Always use new fastening screws and nuts following removal.
→ Observe specified tightening torques.
→ Carry out a visual inspection of all re-used parts.
- Fit the fuse elements according to the wiring diagram and fit the marked connecting lines one after the other in the power distributor and secure with the fastening nuts. → Tightening torque: 5 Nm (3.5 ftlb.)
- Pull the battery leads through the opening into the power distributor (HSB) if necessary.
- Attach the battery leads and secure with the fastening nuts.
→ Tightening torque: 8 Nm (6 ftlb.)
- Connect electric plug connections -1, 2- (-arrow C- ) until they engage securely.
- Clip in connecting lines -arrow D- .
- Close the cover on the power distributor (HSB) until the locking lugs engage securely.
- Slide the power distributor (HSB) into the guide -arrow C- and screw in the fastening screw -arrow D- .