LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2012 >> Panamera 4S >> Repair and Diagnosis >> Accessories & Equipment >> Wiring System (Data Link Connectors, Pwr Dist., Grnd Dist.) >> 97 - Cables -- PANAMERA(970) >> WM 970955 Replacing Sub-Part For Front Fan (Except PANAMERA S Executive, PANAMERA Executive, PANAMERA Turbo Executive, PANAMERA GTS) >> Installing Sub-Part For Front Fan

Installing Sub-Part For Front Fan

  1. Secure sub-part for fan at all four fastening points.
  2. Fit ground strap at ground point for front left longitudinal member and tighten the fastening nut.

    Tightening torque: 9 Nm (6.5 ftlb.) 

    Information 

    Select a place for the joint where there is enough space to join all the lines present.

    Do not cut the lines too short in case they have to be laid in a different position if there is insufficient space in the area of the joint.

    Information 

    The greatest care must be used in the individual work steps for stripping insulation from, crimping, and shrinking/insulating the electric lines.

    The procedure for stripping insulation from, crimping, and shrinking/insulating the electric lines must be complied with and observed. The procedures are described in detail in the Repair kit for Cayenne wire harnesses NR.155-2  .

    Crimping samples must be prepared before beginning work.

    Information 

    Allocation of lines. See appropriate SYSTEM WIRING DIAGRAMS

  3. Crimp the control lines in area -x-  .
    Fig 1: Identifying Front Fan Connection Part Of Sub-Part
    G09814121Courtesy of PORSCHE CARS NORTH AMERICA, INC.
    1. 3.1. Cut off lines in different lengths (due to the shrink-fit connections).
    2. 3.2. Slide shrink-fit hoses onto the lines.
    3. 3.3. Strip 10 mm of insulation off the wires.
    4. 3.4. Crimp lines using crimping sleeves and the hand crimping pliers  from the repair kit for wire harnesses Nr.155-1  .
    5. 3.5. Slide the shrink-fit hoses over the crimp connections and carefully shrink them using the hot-air blower with special nozzle  (recommended accessories for repair kit for wire harnesses) so that they are watertight.
    6. 3.6. Wrap commercially available PVC tape all around the area of the connection points.
    7. 3.7. Secure the repaired area -x-  to the main wire harness with tie-wraps.
  4. Insert B+ line into the Medifuse box and tighten the fastening nut. → Tightening torque: 9 Nm (6.5 ftlb.) 
  5. Close the Medifuse box and secure it at the holder in the left wheel housing.