Installing High-Pressure Pump
WARNING:
Highly inflammable or explosive materials
- Danger of fire or explosion
→ Avoid contact with hot parts or sources of ignition.
→ Use suction to remove ignitable vapors.
→ Attach warning sign in a clearly visible position.
Information
- Always perform a leak test in the high-pressure area after opening the fuel system.
- This is particularly important if components are disassembled and replaced.
- The threaded connections of the fuel lines must be coated with OKS 1710 lubricant (Part no. 000.043.303.27) before being screwed back on again.
- Blow residual fuel out of the lines and high-pressure pump (into a fuel-resistant container or cloth) using compressed air before installation.
- The tightening specifications must be strictly observed.
- Clean sealing surfaces.
- 1.1. Grease O-ring on high-pressure pump with a little Kluber Syntheso Glep (Part No. 000.043.204.68).
Information
Before installing the high-pressure pump, check the position of the driver and move it into installation position by hand if necessary.
Information
- Ensure everything is clean when working on the fuel system.
- Even the smallest particles of dirt can cause problems and damage to the high-pressure system.
- 1.1. Grease O-ring on high-pressure pump with a little Kluber Syntheso Glep (Part No. 000.043.204.68).
- Fit high-pressure pump.
- 2.1. Check the clutch position at the outlet sprocket. Check the deeper groove (approx. 13.5 mm) -arrow- .
- 2.2. Position the high-pressure pump driver -1-
so that the high driving journal -A-
engages in the deeper groove.
- Driver
- Dimension A = 11.5 mm
- Dimension B = 7 mm
- 2.3. Insert the high-pressure pump gently in the fitting bore on the cylinder head.
- Fasten high-pressure pump and place fuel lines.
- 3.1. Coat fuel line union nuts and high-pressure pump screw sockets with lubricant OKS 1700 using a clean brush.
- 3.2. After positioning the high-pressure pump, fit the high-pressure line union nut first, then the low-pressure line union nut. Screw union nuts by hand as far as possible.
- 3.3. Fit and tighten M6 x 25 external Torx screws (E10) -1 and 2-
.
→ Tightening torque: 13 Nm (9.5 ftlb.)
- Installing structure protection.
- 4.1. Position and tighten external Torx screws (E10) M6 x 40 -3-
and M6 x 25 -4 and 5-
.
→ Tightening torque: 13 Nm (9.5 ftlb.)
- 4.1. Position and tighten external Torx screws (E10) M6 x 40 -3-
and M6 x 25 -4 and 5-
.
- Tighten union nut (a/f 14) on high-pressure line. Tool: Crow foot wrench Nr.195-1 -1-
.
→ Tightening torque: 20 Nm (15 ftlb.)
- Tighten union nut (a/f 17) on low-pressure line. Tool: Crow foot wrench Nr.195
.
→ Tightening torque: 20 Nm (15 ftlb.)
- Plug in connector for flow control valve.