Subsequent Work
Information
- When topping up or filling in Pentosin, make sure that it does not come into contact with the coolant hoses. To avoid overflow caused by overfilling, observe the instructions under
- If coolant hoses come into contact with Pentosin, clean them thoroughly with water IMMEDIATELY!
- Replace visibly swollen coolant hoses.
- Fit engine guard
- Fit wheel housing liner
> WM 505619 REMOVING AND INSTALLING FRONT WHEEL HOUSING LINER
- Fit wheel
- After fitting the pressure lines, fill steering hydraulics with Pentosin CHF 202 and bleed the steering system
- Adjust toe-in and read and follow information about steering-gear centre position!
- Calibrate steering-angle sensor