LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2012 >> Cayenne S >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 36 (37 - Automatic Transmission - Actuator, Housing (4.8L Turbo) -- 92A - Cayenne (92A)) >> WM, 373055 Replacing TIPTRONIC Control Unit >> Programming TIPTRONIC Control Unit

Programming TIPTRONIC Control Unit

WARNING: This page is about a different variant/trim than selected.
NOTE: Voltage drop 
  • Risk of irreparable damage to control unit 
  • Risk of damage to control unit 
  • Fault entries in the control unit 
  • Coding in the control unit is aborted 
  • Malfunctions in control unit, even during programming 

    → Prior to disconnecting the control unit, switch off ignition and remove ignition key.

    → Ensure that the power supply is not interrupted during programming.

    → Connect a battery charger with a current rating of at least 90 A to the vehicle battery.

Information 

The PIWIS Tester instructions take precedence since the description may be different with late. Tester releases.

The procedure described here has been structured in general terms. Different text or additional information may appear on the

PIWIS Tester.

  1. > 9818 - PIWIS Tester II must be connected to the vehicle before starting the Tester. Then switch on ignition.
  2. Select the vehicle type under Diagnostics.
  3. Select Transmission control unit in the overview and press F12  to continue.
  4. Select Tiptronic control unit in the control unit overview.
  5. Select the Programming  tab in the menu. 
  6. Select the programming mode Automatic programming  from the Control unit programming  screen and press F12  to continue.
  7. Select the relevant programming rules under Programming  , e.g. V6BT  and press F12  to continue.
  8. Press F8  to start programming.
  9. Once the message Programming was completed successfully  appears, press F12  to continue.
  10. Then press ESC  to exit.