LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2012 >> Cayenne S >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 28 (20 - Fuel Supply, Actuator (4.8L Turbo) -- 92A - Cayenne (92A)) >> WM, 200301 Checking Fuel Quality >> Checking Fuel Quality

Checking Fuel Quality

WARNING: This page is about a different variant/trim than selected.
WARNING: Highly inflammable or explosive materials 
  • Danger of fire or explosion 

    → Avoid contact with hot parts or sources of ignition.

    → Use suction to remove ignitable vapors.

    → Attach warning sign in a clearly visible position.

    → Contain leaked media using non-flammable absorbent material and put it in a container designed for this purpose for disposal in accordance with local requirements.

    → Secure collection containers/vessels to prevent them from tipping over.

Information 

  1. Push the measuring cylinder -1-  into the fixing clip -2-  in the case -Arrow-  .
    G16309048Courtesy of PORSCHE CARS NORTH AMERICA, INC.

    Measuring cylinder in fixing clip in lid of case

  2. Place the spindle sleeve -1-  under the lid of the case -Arrow-  so that the measuring cylinder is horizontal.
    G16309049Courtesy of PORSCHE CARS NORTH AMERICA, INC.

    Placing spindle sleeve under lid of case

  3. Pour 500 milliliters (ml) -Arrow-  of fuel into the measuring cylinder.
    G16309050Courtesy of PORSCHE CARS NORTH AMERICA, INC.

    Pouring fuel into measuring cylinder

  4. Carefully immerse the measuring spindle in the liquid and let it go.

    Do not drop the measuring spindle! 

    G16309051Courtesy of PORSCHE CARS NORTH AMERICA, INC.

    Do not drop the measuring spindle

    1. 4.1 The spindle must be floating in the middle in order to read off the scale value.
      G16309052Courtesy of PORSCHE CARS NORTH AMERICA, INC.

      Position of measuring spindle for reading off value

    2. 4.2 Read off the scale value.
    G16309053Courtesy of PORSCHE CARS NORTH AMERICA, INC.

    Reading off scale value on measuring spindle

  5. Assign the scale value using the table below.
    Scale value (at 20° Celsius) Assessment Comment
    below 0 Case for fuel laboratory (neither petrol nor diesel) Laboratory test required
    0... 5.5 Petrol EN 228  
    4.5... 6.5 E 85  
    approx. 7 E 100 (pure ethanol)  
    7... 9 No evaluation possible (neither petrol nor diesel) Laboratory test required
    9... 11 Diesel in Asia (Russia/India)  
    10... 13 Diesel in accordance with EN 590 (Europe)  
    13... 15 No evaluation possible, "wild mix" Laboratory test required
    15... 17 Biodiesel Laboratory test required
    above 17 Measuring spindle does not stay in the fuel (water-like density) Laboratory test required

    Information 

    • Fuel, fuel mixes and cleaning mixes must be disposed of according to the applicable national regulations. 
  6. After testing the fuel, wash out and wash off measuring equipment thoroughly using the cleaning brush, washing-up liquid and hot water.
    G16309054Courtesy of PORSCHE CARS NORTH AMERICA, INC.

    Cleaning measuring equipment

  7. After analyzing the fuel quality, carry out the required measures.