Home >> Porsche >> 2012 >> Cayenne S >> Repair and Diagnosis >> Engine Mechanical >> Cooling System (Mechanical) >> 19 - Engine - Cooling (4.8L Non Turbo) -- 92A - Cayenne (92A) >> WM, 193817 Draining And Filling Coolant (Includes Bleeding) >> Tools And Materials >> Filling Device - Overview And Setup

Filling Device - Overview And Setup

Information 

Fig 1: Vacuum-Filling Device Components Location
G16308757Courtesy of PORSCHE CARS NORTH AMERICA, INC.

Vacuum-filling device components

1 Adapter K 65  (Fitted instead of the cap of the coolant reservoir.) Not shown! 
2 Hose extension FZ 100  (Fitted between K65 and KVB 01.)
3 KVB 01  (Vacuum gauge with two shut-off valves.)
V1 Shut-off valve V1  (Shut-off valve for the filler hose.)
-V2- Shut-off valve V2  (Shut-off valve for the filler hose - outlet to Venturi nozzle.)
4 Venturi nozzle  (A vacuum is produced in this component using compressed air. Pressure of between 6 and 10 bar must be present. The higher the pressure, the better the vacuum in the vehicle cooling system.)
5 Filler hose  (The cooling system is refilled via this hose.)
6 Return lines  (The compressed air and extracted coolant are drawn off via this hose.)
G16308758Courtesy of PORSCHE CARS NORTH AMERICA, INC.

Illustration of vacuum-filling device setup

1 Return lines
2 Overflow container (bucket or canister)
3 Compressed air connection
4 Compressed air connection (Pressure of between 6 and 10 bar must be present. The higher the pressure, the better the vacuum in the vehicle cooling system.)
5 Filling canister with coolant (It is best to position the canister higher than the reservoir).
6 Adapter K 65 (Fitted instead of the cap on the coolant expansion tank.). General illustration provided here. Use an intermediate cable/extension (FZ 100).
7 KVB 01 (Vacuum gauge with two shut-off valves V1 and V2)
V1 Shut-off valve V1 (Shutoff valve for the filler hose.)
-V2- Shut-off valve V2 (Shutoff valve for the filler hose - outlet to Venturi nozzle.)