Installing Oxygen Sensor Upstream Of Catalytic Converter
NOTE:
Incorrect handling of oxygen sensors
- Damage to oxygen sensors
- Different exhaust emission behavior
→ Do not remove the plastic cap on the thread until just prior to fitting.
→ Protect oxygen sensors from impact of any kind.
→ Do not kink or twist the cables when screwing in the sensors.
→ Do not re-use dirty or damaged components.
Information
- Before installing the oxygen sensors, check that the cover plates are fitted on the catalytic converters.
- If not, retrofit them in accordance with Technical Information.
- The installation is described in the PIWIS information system under → Installing Cover Plate For Exhaust Manifold .
- Visually check the sealing ring -arrow-
and thread on the oxygen sensor for damage.
- 1.1. Replace oxygen sensor if damaged.
- Fit oxygen sensor.
- 2.1. Grease thread of oxygen sensor with a light coating of Optimol Paste MF (000.043.207.07) before refitting. New oxygen sensors are pre-greased for installation.
- 2.2. Fit and screw in oxygen sensor by hand. →246920 REMOVING AND INSTALLING OXYGEN SENSOR UPSTREAM OF CATALYTIC CONVERTER
- 2.3. Make sure that the connecting cable can also turn when installing the oxygen sensor.
- 2.4. Tighten oxygen sensor using accessory for torque wrench: angled open-end/ring wrench Nr.96-3
.
→ Tightening torque: 50 Nm (37 ftlb.) +/-8 Nm (+/-6 ftlb.)
- Route blue connecting cable as far as the oxygen sensor and clip it into the holders. Replace tie-wraps if necessary.
- Fit plug connection for oxygen sensor.
- 4.1. Clip cable plug and connecting cable into the holder. For cylinder bank 1-3, see illustration -1-
, for cylinder bank 4-6, see illustration -1-
.
Courtesy of PORSCHE CARS NORTH AMERICA, INC.
- 4.2. Connect and lock cable plug.
- 4.1. Clip cable plug and connecting cable into the holder. For cylinder bank 1-3, see illustration -1-
, for cylinder bank 4-6, see illustration -1-
.