Installing Front Level Sensor
Information
- In running gear with level adjustment, a level sensor is installed on each spring strut .
- The level sensor is screwed to the body and upper control arm .
- Position level sensor -1-
and holder -4-
and screw in the fastening screw -3-
. → 4X00IN TIGHTENING TORQUES FOR LEVELLING SYSTEM
Make sure that the level sensor linkage is facing outwards. → Installing front sensor for levelling system
- Plug in electric plug connection -2- on the level sensor -1- (-A- ) and lock it -a- .
- Press linkage holder -1-
into the upper trailing arm -2-
(-A-
).
Make sure that the holder -1- is seated correctly in the upper trailing arm -2- (-B- ).
- Press locking pin -3- as far as it will go into the holder -1- (-C- ).