Checking The Antifreeze Content Of The Coolant Using A Refractometer
WARNING: This page is about a different variant/trim than selected.
Information
- Leitenberger display scale. > T10007A - Refractometer
- Leitenberger display scale. > T10007B - Refractometer
- The scale can vary slightly, depending on the manufacturer.
- The ETHYLENE scale must be used for Porsche antifreeze.
- Other commercially available testers can also be used provided correct results are guaranteed.
Refractometer
| Item | Designation of the display | Explanation |
|---|---|---|
| -A- | Scale for propylene-based coolant | Do not use for engine type M48. |
| -B- | Scale for ethylene-based coolant | Coolant such as elf GLACELF SUPRA. Use for engine type M48. |
| -C- | Scale for battery acid | The charge state of a battery can be checked here. The values on the left side indicate the specific gravity of the electrolyte. The battery must be recharged once the charge drops below 1.20. |
| -D- | Scale for alcohol-based windscreen cleaner | The freezing point of the windscreen cleaner can be read off here. |
| -E- | Light/dark limit | In conjunction with the points of intersection of the relevant scales, it specifies the value to be established. |
| -F- | Waterline | The light/dark limit must be located here when sprinkled with distilled water. |
- Using a pipette, take a sample from the coolant reservoir.
Pipette
- Deposit a few drops on the test surface.
Depositing drops on the test surface
- Close the light-diffusing lens. A closed film must form.
Closing the light-diffusing lens
- Using the refractometer, view against a very bright light source. A very clear light/dark limit emerges. The point of intersection between this line and the display scale marks the freezing point of the coolant.
- A freezing point that is too low must be adjusted accordingly.
Information
- The following table specifies how much coolant must be replaced by pure antifreeze in order to adjust the freezing point to -37°C.
| Measured antifreeze protection in°C | Antifreeze quantity to be added (in litres) |
|---|---|
| - 5 | 9 |
| - 10 | 8.5 |
| - 15 | 7.5 |
| - 20 | 7 |
| - 25 | 5 |
| - 30 | 3.5 |
| - 35 | 1.5 |