Technical Data For Air-Conditioning System
| Air conditioning | Refrigerant quantity | Filling capacity of refrigerant oil |
|---|---|---|
| Climatronic | 850 g + 25 g R134a | 195 cm3 + 15 cm3 ND 8 |
| General pressures | bar |
|---|---|
| High-pressure cut-off | 32 |
| Low-pressure cut-off at ambient temperature > 5 °C | 1.4 |
| High-pressure cut-off at ambient temperature < 5 °C | 0.5 |
| Pressure relief valve purge pressure | 40 |
| Refrigerant distribution in circuit | approx. cm3 |
|---|---|
| Compressor | 50 |
| Condenser, 2 x 20 cm 3 | 40 |
| Evaporator | 30 |
| Fluids with containers | 30 |
| Circulating oil quantity in the refrigerant circuit | 60 |